Advanced air purification technology to meet key goals
How would you like the air in your facility to support your goals? Improve profitability in perishables processing and storage operations by eliminating ethylene and other contaminants that harm product quality? Improve IAQ in Class A commercial environments or classrooms?
Your customized Airocide air purification solution will meet your goals with results that far surpass HEPA filtration or chemical treatments. Originally developed for NASA, our patented technology completely destroys airborne pollutants in a closed system. No harmful emissions are produced, just clean air!
Our powerful HD Series has become the global standard in the perishables processing/storage and wine industries. Our GCS Series, first designed for healthcare, is now the choice of leading properties worldwide, from hotels to offices to luxury residential to hospitals.

How Airocide® Air Purifiers Work
Airocide’s patented Photocatalytic Oxidation (PCO) technology completely traps and destroys harmful airborne microorganisms and pollutants that cannot be caught by HEPA filters.
A photocatalyst incorporating TiO2 is irradiated with photons from our proprietary UV lights, forming hydroxyl radicals which reduce to trace elements of CO2 and water. The catalyst surface absorbs and eliminates airborne pollutants like VOCs (including Ethylene), mold, bacteria, pathogens, viruses and odors.
Listed as a Class II Medical Device by the U.S. FDA, Airocide is green and safe. No ozone. No harmful byproducts. Easy to install: just mount, plug in, and it’s ready to go!
Airocide GCS Series Air Purifiers
Airocide’s GCS series is ideal for larger spaces where noise and aesthetics matter. These quiet, elegant units were originally designed for healthcare settings, with white thermoform covers enabling them to blend into their environments. Over time they have become the industry standard in larger settings for not just healthcare, but also for removal of ethylene gas and mold in perishables coolers, as well as to sanitize air in classrooms, premier commercial buildings, and restaurants the world over.

Airocide® GCS-25 Air Purifier
For spaces with dimensions in the range of 2,000 cubic ft (57 cubic meters) to sanitize air by removing ethylene gas, mold, fungi and other pollutants as well as odors. FDA-listed Class II medical devices that produce no harmful byproducts, just clean air.
Length | 465 mm (18.3 in.) |
---|---|
Width | 525 mm (20.7 in.) |
Depth | 115 mm (4.5 in.) |
Weight | 8.34 kg (18.4 lbs) |
Decible | 42 db |
Max input – AC | 100-240 VAC |
Max Current | 1.0 Amp |
Hertz | 50/60 |
Watts | 73w |
Powercord Length | 7.5 ft. |
Cover Material | Thermoform |
Placement | Wall or Ceiling Mount |
Maintenance | Annual Lamp Change (replacement kits available) |
Certifications | ![]() |

Airocide® GCS-50 Air Purifier
For spaces with dimensions in the range of 12,500 – 25,000 cubic ft (354-708 cubic meters) to sanitize air by removing ethylene gas, mold, fungi and other pollutants as well as odors. FDA-listed Class II medical devices that produce no harmful byproducts, just clean air.
Length | 720 mm (28.4 in.) |
---|---|
Width | 581 mm (22.8 in.) |
Depth | 116 mm (4.6 in.) |
Weight | 17.29 kg (38.2 lbs) |
Decible | 46 db |
Max input – AC | 100 – 240 VAC |
Max Current | 2.5 Amps |
Hertz | 50/60 |
Watts | 214w |
Powercord Length | 7.5 ft. |
Cover Material | Thermoform |
Placement | Wall or Ceiling Mount |
Maintenance | Annual Lamp Change (replacement kits available) |
Certifications | ![]() |

Airocide® GCS-100 Air Purifier
For spaces with dimensions in the range of 35,000 cubic ft (991 cubic meters) to sanitize air by removing ethylene gas, mold, fungi and other pollutants as well as odors. FDA-listed Class II medical devices that produce no harmful byproducts, just clean air.
Length | 1065 mm (41.9 in.) |
---|---|
Width | 595 mm (23.5 in.) |
Depth | 117 mm (4.6 in.) |
Weight | 28.35 kg (54 lbs) |
Decible | 49 db |
Max input – AC | 100/240 VAC |
Max Current | 5.0 Amps |
Hertz | 50/60 |
Watts | 462w |
Powercord Length | 7.5 ft. |
Cover Material | Thermoform |
Placement | Wall or Ceiling Mount |
Maintenance | Annual Lamp Change (replacement kits available) |
Certifications | ![]() |
Airocide HD Series Air Purifiers
Airocide’s HD Series, the most powerful in our lineup, are for large spaces with demanding applications where higher CFM outweighs aesthetics and noise, for fast processing and removal of mold, fungi and ethylene. MERV-13 filtration for bioparticulate is an added benefit. Durable metal covers withstand the toughest environments. HDs are deployed worldwide in food, floral, wine, and cannabis industries as well as large public venues.

Airocide HD-1200 Air Purifier
For facilities with dimensions in the range of 3,000 cubic feet (85 cubic meters). Fast processing (high CFM) for removal of mold, powdery mildew, ethylene, bacteria and other pollutants. Filters out bioparticulates. FDA-listed Class II medical device.
Length | 18 in. (0.4572 m) |
---|---|
Width | 7.38 in. (0.187452 m) |
Height | 5.5 in. (0.1397 m) |
Weight | 18 lbs |
Max input – AC | 120 or 220 VAC |
Max Current | 1 Amp / 0.5 Amp |
Watts | 100w |
Powercord Length | 9 ft. |
Maintenance | Annual Lamp Change Filter change every 3 months (replacement kits available) |

Airocide HD-25000 Air Purifier
For facilities with dimensions in the range of 12,500 – 25,000 cubic ft (354-708 cubic meters). Fast processing (high CFM) for removal of mold, powdery mildew, ethylene, bacteria and other pollutants. Filters out bioparticulates. FDA-listed Class II medical device.
Length | 26.25 in. (.679 m) |
---|---|
Width | 18.75 in. (.476 m) |
Height | 8.75 in. (.222 m) |
Weight | 32 lbs (14.514 kg) |
Max input – AC | 120 or 220 VAC |
Max Current | 2 Amps / 1 Amp |
Watts | 180w |
Powercord Length | 9 ft. |
Maintenance | Annual Lamp Change Filter change every 6 months (replacement kits available) |

Airocide HD-TITAN 100 Air Purifier
For facilities with dimensions in the range of 40,000 cubic ft (1,133 cubic meters). Fast processing (high CFM) for removal of mold, powdery mildew, ethylene, bacteria and other pollutants. Filters out bioparticulates. FDA-listed Class II medical device.
Length | 39 in. (.991 m) |
---|---|
Width | 22 in. (.559 m) |
Height | 14 3/8 in. (.365 m) (.991 M. x .559 M x .365 M) |
Weight | 70 lbs (31.75 kg) |
Max Input – AC | 120 or 220 VAC |
Max Current | 4 Amps / 2 Amps |
Watts | 390w / 195w |
Powercord Length | 9 ft. |
Maintenance | Annual Lamp Change Filter change every 6 months (replacement kits available) |

Airocide ACS-100 FG Air Purifier
Food-grade unit with water-proof, tightly sealed encasement for maximum protection in wet environments. For air sanitation in facilities with dimensions in the range of 12,500 – 25,000 cubic ft (354-708 cubic meters) including dairies, fisheries, and other food processing industries with challenging environments.
Length | 59.625″ (1.514 m) |
---|---|
Width | 26.125″ (.664 m) |
Height | 7″ (.178 m) |
Weight | 115 lbs. (52.163 kg) |
Max input – AC | 120 or 220 VAC |
Max Current | 4 amps / 2 amps |
Watts | 408 w |
Powercord Length | 20 ft |
Construction | Aluminum & Grade 306 Stainless Steel |
Maintenance | Annual Lamp Change Filter change annually (replacement kits available) |
Certifications | ![]() |
Note: The guidelines for cubic feet/cubic meters are recommendations based on standard operating conditions. Any extreme environments will require these specs to be adjusted anywhere from 25% to 50%. Your Airocide expert will calculate your specific needs based on variables such as floorplan and design of the space, temperature, power availability, and the sensitivity of contents to airborne VOCs, mold and pathogens to obtain your optimal target disinfection level.